REINFORCED EARTH PRECAST FACING |
 |
|
|
High Adherence
Reinforcing Strips
The reinforcing strips used by The Reinforced Earth Company are
S355JR steel strips with a minimum ultimate tensile strength (UTS)
of 510N/mm2, complying with the requirements of BS EN
10025. Hot-dip galvanized to BS EN ISO 1461.
The strips have a ribbed profile which enhances the adherence of the
strip when placed within a compacted granular fill. The apparent
coefficient of friction
m*,
between the fill and the strip is usually estimated from the current
BBA Certificate No. 99/R106.
Taking account of the sacrificial thickness, the manufacturing
tolerances and partial safety factors, the design strength of each
strip type is:
|
|
|
|
|